Steel Conduit

IMC Conduit (Intermediate Metal Conduit)


IMC is a medium-wall steel electrical conduit, thicker and stronger than EMT but lighter than RSC. Suited to outdoor work, it shields power and signal cables from impact and physical damage, with threaded ends for couplings and fittings.

IMC Conduit (Intermediate Metal Conduit)

IMC Conduit (Intermediate Metal Conduit)


Available from 1/2 in. to 4 in. for a wide range of applications, adding safety, order and stability to the wiring system.

Size and Weight
Conduit sizes : ½, ¾, 1, 1¼, 1½, 2, 2½, 3, 3½ and 4 in.
Standard length : 3,050 mm, with a tolerance of ±6 mm depending on conduit size
Wall Thickness : Approx. 1.79-4.06 mm depending on conduit size
Conduit weight : Minimum weight per 10 lengths with couplings is approx. 25.4-296.1 kg depending on conduit size
Standards : Comply UL 1242 / Comply ANSI C80.6 / TIS 770-2567
Size Table

IMC Conduit (Intermediate Metal Conduit) Size Table

Scroll the table sideways to see all data

SizeOutside Diameter
(mm)
Wall Thickness
(mm)
Length without Coupling
(mm)
Min. Weight per 10 Lengths with Couplings
(kg)
in.mmminmaxminmaxNominalTolerance
½"1620.5720.831.792.163,030±625.4
¾"2126.0126.261.902.293,03034.6
1"2732.5432.892.162.543,02549.9
1¼"3541.4041.782.162.673,02564.3
1½"4147.5248.012.292.793,02579.1
2"5359.7460.122.412.923,025105.2
2½"6372.3172.823.564.063,010186.2
3"7888.0488.543.564.063,010229.0
3½"91100.61101.123.564.063,005263.0
4"103113.18113.693.564.063,005295.1

IMC Conduit (Intermediate Metal Conduit) Features

  • Made from high-quality steel with a durable medium-thick wall for applications that need more protection than EMT.
  • Zinc-coated inside and out for better corrosion resistance and a lower chance of rust.
  • Both ends are threaded for a tight connection to couplings and fittings.
  • Shields power and signal cables from impact and physical damage, improving electrical system safety.
  • Available from 1/2 in. to 4 in.; diameter, wall thickness and weight vary by size.
  • Suited to indoor electrical installations, commercial buildings, factories and areas that need strong wire protection.
  • Standards: Comply UL 1242 / Comply ANSI C80.6 / TIS 770-2567
IMC Conduit (Intermediate Metal Conduit)
How to Use

How to Use

  1. Use to carry power and signal cables, protecting them from physical damage and keeping the wiring system organized.
  2. Measure the run and choose a conduit size that suits the number, size and type of wires before installing.
  3. Use couplings, connectors and fittings made for IMC conduit for strong, safe connections.
  4. Install according to engineering practice and the applicable electrical standards.

Need help choosing the right IMC Conduit (Intermediate Metal Conduit) for your project?

Send us the conduit sizes, quantities and type of installation, and our team will recommend the right products and prepare a quotation right away.

LINE

Contact LINE

Chat with us instantly

@bpsofficial
LINE QR @bpsofficial

Call Us

Available for consultation daily

Request a Quote

Response within 1 business day

Request a Quote

Map

BPS head office and warehouse

Head office

BPS Technology Public Company Limited

25/34-38, 47-51 Sukhumvit Road, Pak Nam, Mueang Samut Prakan, Samut Prakan 10270

Open in Google Maps
Warehouse

BPS Technology Warehouse

46/2 Moo 23, Bang Phli Yai, Bang Phli, Samut Prakan 10540

Open in Google Maps
line