Flexible Metal Conduit

PVC-Coated Flexible Steel Conduit for General Use


Liquid-tight PVC-coated flexible steel conduit for general use, designed to carry and protect power, cable and signal lines from impact, dust, moisture and the outside environment, within the product’s rated properties. Its flexible metal core with an outer PVC jacket adds protection and reduces the risk of physical damage.

Because it can be bent and re-routed, it suits tight spaces, areas where conduit routing is restricted, connections to electrical equipment, installations that need flexibility, and locations with continuous vibration or movement.

PVC-Coated Flexible Steel Conduit for General Use

PVC-Coated Flexible Steel Conduit for General Use


Available from 1/2 in. to 4 in. for electrical systems in buildings, factories and industrial equipment, keeping wiring organized, easy to install and better protected from the surrounding environment.

Product and Size Information
Product type : PVC-Coated Flexible Steel Conduit for General Use
Available sizes : From ½ in. to 4 in.
Description : Flexible metal conduit that bends to follow the installation, with an outer PVC jacket
Compatibility : Carries and protects wires, cables and signal lines.
Standards : TIS 770-2567
Size Table

PVC-Coated Flexible Steel Conduit for General Use Size Table

Scroll the table sideways to see all data

SizeOutside DiameterInner DiameterBend RadiusLengthWeight
in.mmin.mmin.mmin.mmftmlbkg
½"200.84021.300.64216.304.01002006062.928.6
¾"251.05026.700.84021.304.01001003042.619.4
1"321.31533.401.06626.904.01151003079.636.2
1¼"401.66042.201.41035.704.5175501550.623.0
1½"501.90048.301.60040.807.0200501565.529.8
2"632.37560.302.04551.809.5250501587.139.6
2½"752.87573.002.50564.0012.0300257.556.525.7
3"803.50088.903.10078.8013.5350257.579.636.2
4"1004.500114.304.040102.5017.0450257.594.643.0

PVC-Coated Flexible Steel Conduit for General Use Features

  • Conduit for wires and cables, made from flexible metal with an outer PVC jacket that bends and routes easily to fit the installation area.
  • Designed to protect wires from impact, dust, moisture and dirt.
  • Suited to tight spaces, corners, connection points and areas where routing is restricted.
  • Can be used where there is vibration or movement, provided the product chosen is rated for that application.
  • The outer PVC layer adds protection against moisture and the environment; the actual water and dust protection depends on the conduit, fittings and installation method.
  • Reduces the risk of wires being directly exposed and keeps wiring organized.
  • Available from 1/2 in. to 4 in. for a wide range of applications.
  • Works with liquid-tight connectors and supports that match the conduit type and size.
  • Suited to general electrical work, equipment installation and industrial applications that need extra wire protection.
  • Standards: TIS 770-2567
PVC-Coated Flexible Steel Conduit for General Use
How to Use

How to Use

  1. Choose liquid-tight PVC-coated flexible conduit that suits the number, size and type of power or signal cables to be pulled.
  2. Measure and plan the route to suit the area, taking connections, electrical equipment and restricted areas into account.
  3. Cut the conduit to length and check that the ends have no sharp metal edges that could damage the PVC layer or wire insulation.
  4. Bend the conduit to fit the installation area, avoiding kinks or over-tight bends, and keep to the manufacturer’s minimum bend radius.
  5. Fit liquid-tight connectors that match the conduit type and size, especially at boxes, panels or equipment that need moisture protection.
  6. Support the conduit securely to suit the area, preventing sagging, movement or excessive strain.
  7. Check the inside and ends of the conduit for sharp edges or obstructions that could damage wire insulation.
  8. Pull wires through carefully without excessive force, and do not exceed the specified fill.
  9. Check connections, fittings, seals and box entries according to the installation method to achieve the required water and dust protection.
  10. Check the run, connections and supports before energizing. Disconnect power during installation and have the work done by a qualified electrician.

Need help choosing the right PVC-Coated Flexible Steel Conduit for General Use for your project?

Send us the conduit sizes, quantities and type of installation, and our team will recommend the right products and prepare a quotation right away.

LINE

Contact LINE

Chat with us instantly

@bpsofficial
LINE QR @bpsofficial

Call Us

Available for consultation daily

Request a Quote

Response within 1 business day

Request a Quote

Map

BPS head office and warehouse

Head office

BPS Technology Public Company Limited

25/34-38, 47-51 Sukhumvit Road, Pak Nam, Mueang Samut Prakan, Samut Prakan 10270

Open in Google Maps
Warehouse

BPS Technology Warehouse

46/2 Moo 23, Bang Phli Yai, Bang Phli, Samut Prakan 10540

Open in Google Maps
line